Antminer 17&19 series diode resistance & voltage values for reference
What is the value of the voltage and resistance of the Hash board under normal operation? ZEUS MINING provides you with the normal value of each test point of the Antminer 17&19 series hash board for your reference when repairing the hash board.
(Multimeter Model: Fluke 15B+)
S17 Diode(resistance)&Voltage Value for reference:
# | BI/BO | RST | RX/RI | TX/CO | CLK | LDO 1.8V | LDO 0.8V |
Diode Value (Resistance) | 1200±20 | 1200±20 | 420±20 | 1200±20 | 1200±20 | 400±20 | 20±5 |
Voltage Value | 0 | 1.7±0.1 | 1.7±0.1 | 1.7±0.1 | 0.7-0.9 | / | / |
S17+ Diode(resistance)&Voltage Value for reference:
# | BI/BO | RST | RX/RI | TX/CO | CLK | LDO 1.8V | LDO 0.8V |
Diode Value (Resistance) | 1200±20 | 1200±20 | 420±20 | 1200±20 | 1200±20 | 400±20 | 20±5 |
Voltage Value | 0 | 1.7±0.1 | 1.7±0.1 | 1.7±0.1 | 0.7-0.9 | / | / |
S17e Diode(resistance)&Voltage Value for reference:
# | BI/BO | RST | RX/RI | TX/CO | CLK | LDO 1.8V | LDO 0.8V |
Diode Value (Resistance) | 1015±50 | 970±50 | 500±50 | 1015±50 | 1015±50 | 400±50 | 25±5 |
Voltage Value | 0 | 1.7±0.1 | 1.7±0.1 | 1.7±0.1 | 0.7-0.9 | / | / |
T17 Diode(resistance)&Voltage Value for reference:
# | BI/BO | RST | RX/RI | TX/CO | CLK | LDO 1.8V | LDO 0.8V |
Diode Value (Resistance) | 1200±20 | 1200±20 | 420±20 | 1200±20 | 1200±20 | 400±20 | 20±5 |
Voltage Value | 0 | 1.7±0.1 | 1.7±0.1 | 1.7±0.1 | 0.7-0.9 | / | / |
T17+ Diode(resistance)&Voltage Value for reference:
# | BI/BO | RST | RX/RI | TX/CO | CLK | LDO 1.8V | LDO 0.8V |
Diode Value (Resistance) | 1200±20 | 1200±20 | 420±20 | 1200±20 | 1200±20 | 400±20 | 20±5 |
Voltage Value | 0 | 1.7±0.1 | 1.7±0.1 | 1.7±0.1 | 0.7-0.9 | / | / |
T17e Diode(resistance)&Voltage Value for reference:
# | BI/BO | RST | RX/RI | TX/CO | CLK | LDO 1.8V | LDO 0.8V |
Diode Value (Resistance) | 1015±50 | 970±50 | 500±50 | 1015±50 | 1015±50 | 400±50 | 25±5 |
Voltage Value | 0 | 1.7±0.1 | 1.7±0.1 | 1.7±0.1 | 0.7-0.9 | / | / |
S19 Diode(resistance)&Voltage Value for reference:
# | BI/BO | RST | RX/RI | TX/CO | CLK | 1.8V | 0.8V |
Diode Value (Resistance) | 1220±20 | 980±20 | 390±20 | 1220±20 | 1220±20 | 440±20 | 20±5 |
Voltage Value | 0 | 1.7±0.1 | 1.7±0.1 | 1.7±0.1 | 0.7-0.9 | / | / |
S19 Pro Diode(resistance)&Voltage Value for reference:
# | BI/BO | RST | RX/RI | TX/CO | CLK | 1.8V | 0.8V |
Diode Value (Resistance) | 1220±20 | 980±20 | 390±20 | 1220±20 | 1220±20 | 440±20 | 20±5 |
Voltage Value | 0 | 1.7±0.1 | 1.7±0.1 | 1.7±0.1 | 0.7-0.9 | / | / |
Remark: the vaules here are from Fluke 15B+ and they vary in accordance with the multimeter used for measurement. Meanwhile, due to the different batches and models of the measured hash board, the vaules may also vary, please take the actual results as standard.