Bitcoin is soaring; which altcoins will generally rise? The world of cryptocurrencies is developing at a breakneck pace. As interest in digital assets increases, investing in the right cryptocurrency can provide an excellent opportunity to earn high returns. Unfortunately, whether you are an experienced investor or a beginner, navigating the complex world of decentralized currencies can be difficult. But don't worry; we've got you covered! This article will reveal the top six cryptocurrencies to consider buying in 2023. MATIC Polygon, formerly known as Matic Network, is a blockchain platform that facilitates the development and scaling of Ethereum infrastructure. It transforms Ethereum into a multi-chain system and provides a common framework for developing various types of applications. Besides that, Polygon SDK can be used to create optimistic rollup chains, ZK rollup chains, and standalone chains. The platform can process up to 65,000 transactions per second on a single sid
How to solve the problem that the hash board does not start on the Antminer S17 Pro?
The temperature sensor is mainly used to sense the temperature of the hash board and its surroundings. If it is damaged, it will cause abnormal temperature readings, and the hash board will not start when the temperature is too low (the backstage log shows that the temperature sensor reading failed), or the Antminer S17 Pro stops running when the temperature is too high. So when the temperature sensor chip fails, you can refer to the following methods for troubleshooting.
Check method:
1. Most temperature sensor chip failures are caused by chip pseudo soldering. It is necessary to measure the chip voltage and ground value with a fluke 15b+ multimeter to troubleshoot and find a hash board of the same model or another good hash board for data comparison. If the temperature sensor chip is faulty, it can be replaced directly.
2. If the temperature sensor chip is normal, the chip that the temperature sensor circuit will pass through may be abnormal, and the faulty chip can be replaced.
Test method: Use fluke 15b+ multimeter DC gear and diode gear, red test lead to connect to the corresponding heat sink, black test lead to test. Compare the measured chip data with the standard chip data. If an abnormality is found, it is recommended to replace the faulty BM1397 chip directly.