ASIC Miner ICERIVER KAS KS0 Profitability In the realm of cryptocurrency mining, the Iceriver KAS KS0 miner has garnered widespread attention. Tailored specifically for the Kaspa network's KHeavyHash algorithm, it boasts high hashing power and low power consumption, making it an ideal choice for many miners. In this article, we will comprehensively assess IceRiver KS0 profitability while considering the Kaspa market conditions and the attributes of KS0 miner. Kaspa Market Dynamics Kaspa is a vibrant cryptocurrency network aimed at delivering high performance and scalability for everyday transactions. At the time of writing this article, the Kaspa coin trades at approximately $0.04959. But it's essential to note that cryptocurrency markets are highly susceptible to price volatility. Hence, investors must remain vigilant about market dynamics. Additionally, the Kaspa network's mining difficulty and reward mechanisms play a role in mining returns. Attributes of the IceRiver KS...
How to solve Antminer T17+ hash board find 0 asic?
The following kernel log faults are from the backstage of the Antminer T17+, and other models of Antminers are for reference only.
Fault: find 0 asic
Solution:
1. First, rule out the problem of the data cable or the problem of the Antminer T17+ control board. Swap the data cable of the Antminer T17+ hash board that displays "find 0 asic" with the data cables of the other two standard hash boards (only the side of the hash board is replaced) to eliminate the source of the fault.
2. Use the fluke 15B+ multimeter to check whether the voltage of the total voltage domain is normal, such as abnormal. It is necessary to check whether the PIC, MOS tube, and boost circuit voltage are abnormal.
3. Check whether the RI signal is normal and directly find the RI signal of a group of chips on the edge of the domain from the middle domain for detection. If it is normal, we will check it forward; if it is abnormal, check it backward.
T17+ hash board RI signal transmission direction: (from No.44 to No.1, the direction of the red arrow)
4. If the kernel log and test fixture test results show "ASIC=0 or NO hash board", check whether the voltage of the chip's RI signal and the ground value is abnormal.
RI signal voltage detection method: adjust the fluke 15B+ multimeter to the DC gear, and place the red and black test pens on the heat sink and RI of the same domain respectively.
RI signal to ground value detection method: adjust the fluke 15B+ multimeter to the diode gear, the red test pen is placed on the heat sink of the same domain, and the black test pen is detected.
Whether the measured result is abnormal can be compared with the resistance value of other chips in the same domain. If there is any abnormality, most of them are caused by chip pseudo soldering or chip damage. Solder it twice first. If it cannot be solved, replace the faulty BM1397 chip.